OpenUtilities Substation Help

Wire Tag Format Dialog

This dialog lets the user select the wire properties that will be displayed in the drawing and configure how they will appear. The user can combine other elements with the wire tag (wire number) to create a more complex wire ID.

Accessed when the user clicks the Edit button from the Standard field in the Options > Wire Settings > Label Preferences

SettingDescription
Profile Name This field displays the name of the current label profile. The profile is a saved format. You can create new profiles, save them and reload them as your project needs require.
Save Profile Saves changes to the current profile. If desired, you can change the entry in the Profile Name field and save the changed profile under a different name.
Load Profile Click to load a previously saved profile.
Available Elements On the left side of the dialog is a list of available elements that can be added to the wire label.
Add to Expression To add an element, select it, and then click the Add to Expression button. It will then be shown on the right side of the dialog as part of the label.
Currently Selected Elements The right side of the dialog displays the currently selected label elements. Below this is an example of what the label will look like in an actual drawing.
Reset Reloads the combination of elements that you had when you entered the dialog.
Clear Empties the field of all selected elements.
Remove Element To remove an element from the label, select it, then either press the <Delete> key or right click on the element and select Delete from the menu.
Prefix and Suffix

These fields allow you to define a character string that will be placed at the beginning (Prefix) or end (Suffix) of the label element. These fields only become active when one of the added elements is selected.

The Width and Fill with fields allow you to set the number and type of characters that will be used for the selected label element. These fields become available when you select a label element and then select the Fixed number of characters check box. (If you do not select this check box the software will use as many characters as necessary for a given value.)

The entry in the Width field sets the number of digits that will be used for the value (more will be used if necessary).

The Fill with field defines the character that will be used if necessary to fill out the value to match the width value.

Example: Page Number set to Width 3, Fill with 0. Labels on page 2 will use the value 002. Labels on page 13 will use the value 013. Labels on page 3333 will use the value 3333.

Duplicate Character section

The options in this section allow you to format how labels will be distinguished when more than one label appears on the same line:

  • First number/character - This field defines how the labels will be marked, numbers or letters, and what the first value will be.
  • Separator - This field defines the character that will divide the value from the rest of the wire label.
  • Suppress first occurrence - Is this option is selected, then the first item on the line will not have the additional value, but succeeding items will. For example: 102, 102.1, 102.2.
OK

Saves the changes and closes the dialog. When you have made the desired changes to the wire label format, use the Save Profile button to save the changes for all future projects using the profile.

If you have not used the Save Profile option, the changes will only apply to the current project.